GRID-FLEX
Built for 800 VDC from the ground up.
GRID-FLEX
Power for AI data centers, energy storage and microgrids. 800 kW per cabinet, up to 3.2 MW per block.
Utility AC in.
800 VDC out.
Data centers are moving to 800 VDC. Tritium has been doing 800 VDC distribution for over two decades, across 23,000+ field assets. GRID-FLEX brings that experience to the data hall: modular, liquid-cooled cabinets on a shared DC bus, IP65 sealed to sit outdoors.
Built to clear
interconnection.
Utilities approve projects that help the grid, not just draw from it. GRID-FLEX ships with the grid-support behaviour interconnection studies ask for, so the review is about your site, not your rectifier.
Less energy lost in conversion means less heat to reject and more of your connection delivered as usable DC.
Voltage support and power-factor correction delivered on demand, without a separate compensator.
Stays connected and supports the grid through voltage and frequency excursions instead of tripping off.
Most backup power waits.
This one works.
The same block that protects the site manages its energy the rest of the time: filling storage when power is cheap, trimming the peak when it is not, and responding to utility demand-response calls. One day, one block:
One platform.
Wherever power is critical.
AI & Data Centers
800 VDC to the hall, with the grid-support behaviour utilities ask for at this scale.
BESS & Renewables
800 VDC interface for storage, solar and hybrid plants, with isolated DC:DC on the same bus.
Microgrids
Grid-tied or islanded, and moves between the two without re-engineering.
Industrial & Critical Sites
Reliable megawatts for plants, campuses and critical facilities. N+2 redundant, IP65 sealed, and built to integrate storage and on-site generation.
Port-side Power
Shore power and electrified cargo handling, IP65 sealed for coastal duty.
Three cabinets.
One power block.
AC & DC Bays
AC and DC switching bays. Terminates the incoming feed and carries protection, isolation and monitoring for both sides. Presents the DC bus to whatever the site needs: busway, combiner boxes or a distribution board.
GRID-FLEX Rectifier
AC:DC power cabinet. Sixteen liquid-cooled 50 kW silicon-carbide modules on two independent banks deliver 800 kW per cabinet at 98.5% efficiency, with reactive power support and fault ride-through. N+2 by design: any 14 of 16 modules carry the full 800 kW.
GRID-FLEX Link
Isolated DC:DC power cabinet on the same bus. Adds galvanic isolation and independent voltage regulation for DC-coupled storage, generation, or loads that need something other than 800 V.
One to four Rectifiers.
Then blocks in parallel.
Blocks are independent and repeatable, each with its own feeders, cooling and protection. Parallel blocks to 9.6 MW and beyond. Buy the blocks you need today and add the next as load arrives, so spend tracks demand instead of a day-one forecast.
See GRID-FLEX
on your site.
Our engineers will help you spec blocks, distribution and a deployment plan for your site.